GD20-0R4G S2 Single Phase Vector Control VFD
Product Details:
- Product Type Control VFD
- Application Industrial, Electrical
- Color Black
- Warranty Yes
- Click to View more
GD20-0R4G S2 Single Phase Vector Control VFD Price And Quantity
- 10 Unit
GD20-0R4G S2 Single Phase Vector Control VFD Product Specifications
- Black
- Control VFD
- Yes
- Industrial, Electrical
GD20-0R4G S2 Single Phase Vector Control VFD Trade Information
- Cash Advance (CA)
- 100 Unit Per Month
- 5 Days
- All India
Product Description
As a well-recognized enterprise, we are eagerly indulged in proposing the world's best GD20-0R4G S2 Single Phase Vector Control VFD. This type of variable frequency drive is mostly utilized in industrial applications for controlling motor speed that makes automation of machine better and saving efficient. Easy to set up, and convenient to operate, it is made of selected components, and powder coated metal housing with well-developed electrical engineering technology. GD20-0R4G S2 Single Phase Vector Control VFD can also be availed in different models, powers and configurations.
Power Input | Input voltage (V) | 1PH 220V (-15%)-240V(+10%) |
Input current (A) | Refer to the rated value | |
Input frequency (Hz) | 50Hz or 60HZ, allowed range: 47-63Hz | |
Power Output | Output motor capacity (kW) | Refer to the rated value |
Output current (A) | Refer to the rated value | |
Output voltage (V) | 0-input voltage, error<5% | |
Output frequency (Hz) | 0-400Hz | |
Technical Control Features | Control mode | SVPWM, SVC |
Adjustable-speed ratio | 1:100 | |
Speed control accuracy | +0.2% (SVC) | |
Speed fluctuation | + 0.3% ( SVC) | |
Torque response | <20ms (SVC) | |
Torque control accuracy | 10% | |
Starting torque | 0. 5H2/150% ( SVC) | |
Overload capability | 150% of rated current: 1 minute | |
Running Control Features | Frequency setting method | Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting, MODBUS communication setting |
Auto-adjustment of the voltage | Keep a stable voltage automatically when the grid voltage transients | |
Fault protection | Provide comprehensive fault protection functions: over-current, over-voltage, under-voltage, over-heating, phase loss and overload, etc. | |
Peripheral Interface | Analog input | 1 (Al2) O-10V/0-20mA and 1 (AIS) -10-10V |
Analog output | 2 (AO1, AO2) 0-10V/0-20mA | |
Digital input | 4 common inputs, the Max. frequency: 1KHz; 1 high speed input, the Max. frequency: 50kKHz | |
Digital output | 1 Y1 terminal output; | |
Relay output | 2 programmable relay outputs | |
Other | Mountable method | Wall and rail mountable |
Braking unit | Embedded | |
EMI filter | Optional filter: meet the degree requirement of IEC61800-3 C2, lEC61800-3 C3 | |
Temperature of the running environment | -10-50oC Above 40oC, derate 1% for every additional 1oC. | |
Altitude | <1000m Above 1000m, derate 1% for every additional 100m. | |
Protective degree | IP20 | |
Safety | Meet the requirement of CE | |
Cooling | Fan cooling |